41 results for “Air balancing”
- ServiceAir balancing (TAB)
We measure the airflow at every diffuser, grille and fan, adjust the system until it matches the design, and give you a report that proves it.
- ServiceResidential air balancing
If one bedroom is always cold and another always stuffy, your system probably isn’t sending air where the house needs it. We measure every room and fix the balance.
- GuideAir balancing procedures and instruments
Learn the instruments used to measure airflow and pressure, and the step-by-step procedure for balancing constant volume and VAV air systems.
- TopicTesting, balancing and commissioning
Proving systems work as designed, from airflow readings to functional tests.
- GuideVenturi air valves explained
Learn how a venturi air valve works, why it is pressure independent without a flow sensor, how it is controlled, and where it is used in critical spaces.
- GuideWhat testing, adjusting and balancing involves
A plain-language explanation of TAB: what is measured, how air and water systems are adjusted to design, and how TAB fits with commissioning.
- GuideMake-up air units: direct-fired and indirect-fired
Learn how direct-fired and indirect-fired make-up air units heat outdoor air, the code and safety rules that limit where each can be used, and how to size and control them for kitchens, warehouses and industrial spaces.
- ServiceWater balancing (hydronic)
We measure the water flow through every coil, pump and balancing valve in your heating or cooling system and set it to design, so every zone gets the capacity it was designed for.
- GuideAir density, altitude and HVAC design in Calgary and the Rockies
Learn how elevation changes air density, which HVAC calculations and selections need correction, and what to check when designing, balancing or commissioning systems in Calgary and mountain communities.
- IndustryCooling solutions for data centers
Cooling design, containment and commissioning for server rooms up to full data halls.
- IndustryHVAC for pharmacies and sterile compounding
Compounding rooms that meet USP and NAPRA, with the pressures and air changes to prove it.
- IndustryHVAC for retail stores and shopping centres
Tenant fit-outs, rooftop unit replacements and energy savings across a portfolio.
- IndustryHVAC for hospitals and healthcare facilities
Operating rooms, isolation rooms and clinics designed and verified to CSA Z317.2.
- IndustryHVAC for restaurants and commercial kitchens
Kitchen exhaust, make-up air and dining room comfort, designed and balanced together.
- ServiceDuct leakage testing
We pressurize sections of ductwork and measure how much air escapes, so leaks are found and sealed before the ceilings close.
- GuideReading a TAB report
A section-by-section guide to TAB reports for owners, engineers and facility managers, with the warning signs that a report needs a closer look.
- GuideFan laws and how to apply them
Learn the fan affinity laws, how to use them to predict fan performance after speed or density changes, and why real VAV systems save less energy than the cube law suggests.
- GuideCommercial kitchen ventilation and NFPA 96
Learn how kitchen exhaust hoods, grease ducts, fans, fire suppression and make-up air work together, what NFPA 96 requires, and how to keep a kitchen system safe and balanced.
- GuideHVAC troubleshooting: hot and cold complaints
Learn a step-by-step method for diagnosing hot and cold complaints in commercial buildings, and the most common causes at the zone, system and plant level.
- GuideExhaust system design for commercial buildings
A practical overview of commercial exhaust systems: required exhaust rates, fan types and locations, discharge and re-entrainment, makeup air and code requirements.
- GuideCommon deficiencies found during commissioning
A practical list of the problems commissioning providers find again and again, grouped by system, with the root causes and the steps that prevent them.
- GuideDuct design methods: equal friction, static regain and more
A practical comparison of the main duct sizing methods used in commercial HVAC, with typical design values and guidance on choosing the right method for a project.
- ServiceCleanroom HVAC design
We design HVAC for cleanrooms and controlled environments: the air change rates, HEPA filtration, pressure cascades and temperature and humidity control that hold a space to its ISO class or GMP grade.
- ServiceControl system verification
We check that every sensor reads correctly, every actuator moves when it’s told to, and the control sequences do what the engineer wrote.
- IndustryHVAC solutions for property managers and building owners
Fewer complaints, lower operating costs and life-safety testing done on schedule.
- ServiceNew HVAC design
We design heating, ventilation and air conditioning for new buildings, additions and major renovations. We join the architect’s team as the mechanical consultant, or work directly for the owner, from the first concept through permit, tender, construction and handover.
- IndustryHVAC and ventilation for industrial facilities
Process exhaust, make-up air and plant heating that protect workers and cut energy.
- GuideWater source heat pump systems
Learn how a water source heat pump system moves heat around a building through a common water loop, how the loop is kept within its temperature range, and the design and maintenance issues that decide its performance.
- GuideDuct leakage testing procedures
Learn how ductwork is pressure tested for leakage, how allowable leakage is calculated from SMACNA leakage classes, and how to plan testing so it does not delay construction.
- GuideOngoing and monitoring-based commissioning
Understand the difference between ongoing commissioning and monitoring-based commissioning, what they require, and how to run a program that keeps savings in place.
- GuideSeasonal testing and deferred commissioning
Learn which HVAC functions cannot be fully tested at turnover, how to plan seasonal testing, and how to make sure deferred tests actually happen.
- GuideIntegrated systems testing and CAN/ULC-S1001
Learn how integrated testing verifies that fire protection, life safety and HVAC systems work together, the role of the integrated testing coordinator, and how to prepare.
- GuideTAB certification bodies: AABC, NEBB and TABB
Understand what AABC, NEBB and TABB certification means, how the three programs differ, and what owners and engineers should write into a TAB specification.
- GuideDuctless mini-splits in commercial applications
Learn where ductless mini-splits make sense in commercial buildings, how to select and locate them, and the common pitfalls with ventilation, condensate, cold weather and maintenance.
- GuideFan selection: curves, efficiency and system effect
Learn how to read fan and system curves, choose an efficient fan type and operating point, and avoid the installation details that rob fans of performance.
- GuideSolar heat gain through glazing and how to control it
Learn how solar radiation enters buildings through glazing, how to read window performance ratings, and which glazing, shading and control strategies reduce cooling loads and glare.
- ServiceBuilding commissioning
Commissioning checks that a new building’s systems are designed, installed and operating the way the owner needs, and that the people running the building know how to keep them that way.
- ServiceHigh-efficiency HVAC upgrades
When equipment is due for replacement, it’s the cheapest moment to upgrade. We help you choose higher-efficiency systems that cut energy use, emissions and operating costs.
- GuideBelt drives vs direct drives
Learn how belt drives and direct drives differ in energy use, maintenance and adjustability, and when converting a fan to direct drive makes sense.
- GuideFan filter units vs ducted HEPA systems
Learn how fan filter units and centrally ducted HEPA systems differ, and which factors decide the better choice for a given cleanroom size, class and budget.
- GuideCooling tower selection and winter operation
Learn how cooling tower types compare, what drives selection, and the freeze protection and control strategies that let towers operate safely in cold Canadian weather.